Back
placeholder TS8290-1
placeholder TS8290-2
placeholder TS8290-3
placeholder TS8290-4
placeholder TS8290-1
placeholder TS8290-2
placeholder TS8290-3
placeholder TS8290-4

TS8290 Portable Benchtop Spectrophotometer

TS8290 portable benchtop spectrophotometer uses a built-in silicon photodiode array (40 pairs of dual-row) sensors and an imported whiteboard. It also takes into account the measurement speed and the convenience of operation. Rotating and pressing structure makes testing more convenient. The repeatability ΔE*ab of TS8280 portable benchtop spectrophotometer is easily controlled within 0.05, and the inter-instrument error ΔE*ab is controlled within 0.15. The measurement is accurate and can be used for accurate color analysis and transmission in the laboratory.

Inquiry
(+86)010-5653 8958
  • Product description
  • Product parameter
  • Product video

TS8290 Portable Benchtop Spectrophotometer


TS8290-实物.jpg


Features:

1. It adopts the internationally-used D/8 structure, compatible with SCI/SCE measurement, and supports SCI+SCE rapid measurement at the same time

The TS8290 benchtop spectrophotometer adopts the internationally applicable D/8 illumination observation conditions, SCI/SCE (including specular reflection/not including specular reflection) synthesis technology, and supports SCI+SCE simultaneous rapid measurement, the test time is about 3.2 seconds.

TS8290-特点1.jpg

2. Silicon photodiode array (dual 40 array) sensor

Larger area dual 40 array sensor, strong light will not saturate, low light sensitivity higher and wider spectral response range, ensuring the measurement speed, accuracy, stability and consistency of the instrument.

TS8290-特点2.jpg

3. Multiple color measurement spaces, multiple observation light sources

TS8290 benchtop spectrophotometer provides CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 color space, as well as D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) multiple observation light sources, which can meet the special measurement requirements under different measurement conditions.

TS8290-特点3.jpg

4. Adopt a combined full-spectrum LED light source and UV light source

The full-band balanced LED light source ensures sufficient spectral distribution in the visible light range, avoids the lack of spectrum of white light LEDs in specific wavelength bands, and ensures the measurement speed of the instrument and the accuracy of the measurement results. Professional UV light sources ensure UV testing more reliable.

TS8290-特点4.jpg

5. Metrological verification report

Each TS8290 benchtop spectrophotometer has been verified and tested, and the instrument is verified according to the measurement standards of the authoritative verification department at the factory, and the measurement data is traced to the National Institute of Metrology to ensure the authority of the instrument test data.

6. Camera locating, can clearly observe the measured area

The TS8290 portable benchtop spectrophotometer has a built-in camera for framing and positioning. Through the real-time framing of the camera, it can accurately determine whether the measured part of the object is the center of the target, which improves the measurement efficiency and accuracy.

TS8290-特点6.jpg

7. Industrial-grade high-definition touch screen, easy-to-use user interface

Using a 7-inch industrial-grade high-definition touch screen, the control is smooth, and the easy-to-use user interface makes the operation comfortable, convenient and easier to use.

TS8290-特点7.jpg

8. Color management software

The SQCX quality management software matched with the TS8290 benchtop spectrophotometer is suitable for quality monitoring and color data management in various industries. Data the user's color management, compare color differences, generate test reports, provide a variety of color space measurement data, and customize customer color management.

TS8290-特点8.jpg


Application:

The TS8290 portable benchtop spectrophotometer is equipped with a Φ30mm measuring aperture, which is suitable for measuring large-area samples, meeting the requirements of accurate color measurement and quality control in textile and garment printing and dyeing, plastic electronics, ceramics and other industries; it can be used for fluorescent sample measurement

Model
TS8290
Optical Geometry
D/8 (diffuse illumination, 8° direction reception);
SCI/SCE measurement; include UV/exclude UV measurement;
Comply with standard CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7
Features
Φ30mm measuring aperture, suitable for measuring large area samples;
Standard configuration of rotary pressing structure, more convenient for testing;
Accurate measurement, can be used for accurate analysis and transmission of laboratory colors;
It is used for accurate color measurement and quality control in textile and garment printing and dyeing, plastic electronics,
ceramics and other industries; it can be used for fluorescent sample measurement.
Integrating Sphere Size
Φ152mm
Light Source
Combined full spectrum LED light source, UV light source
Spectrophotometric Mode
Plane Grating
Sensor
Silicon photodiode array (40 groups in dual rows)
Wavelength Range
400~700nm
Wavelength Interval
10nm
Semiband Width
10nm
Measured Reflectance Range
0-200%
Measuring Aperture
Φ30mm/Φ25.4mm
Specular Component
Simultaneously test SCI/SCE
Color Space
CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2)
Color Difference Formula
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
Other Colorimetric Index
WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
Metamerism index Mt,
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° gloss, 555 color classification
Observer Angle
2°/10°
Illuminant
D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30)
Displayed Data
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset
Measuring Time
About 1.5s (Measure SCI & SCE about 3.2s)
Repeatability
Chromaticity value:MAV/SCI, within ΔE*ab 0.05 (After the instrument is warmed up and calibrated, measure the average value of the
whiteboard 30 times at an interval of 5s)
Inter-instrument Error
MAV/SCI, Within ΔE*ab 0.15(Measured average value of 12 tiles of BCRA series Ⅱ)
Measurement method
Single measurement, average measurement (2~99 times)
Locating
Camera lpcating
Dimension
L*W*H=425X250X470mm
Weight
Approx. 18kg
Power
AC 24V, 3A Power adapter power supply
Illuminant Life Span
5 years, more than 3 million times measurements
Display
7-inch TFT color LCD, Capacitive Touch Screen
Data Port
USB, Bluetooth®5.0, Trigger switch interface
Data Storage
Standard 1000 Pcs, Sample 30000 Pcs(SCI/SCE counts as one piece of data)
Language
Simplified Chinese, Traditional Chinese, English
Operating Environment
0~40℃, 0~85%RH (no condensation), altitude: less than 2000m
Storage Environment
-20~50℃, 0~85%RH (no condensation)
Standard Accessory
Power adapter, data cable, manual, quality management software (download from official website), calibration box, measuring
aperture, rotating bracket
Optional Accessory
Mini printer, Foot switch
Notes
The specifications are subject to change without notice.


Recommended Products

IF YOU HAVE MORE QUESTIONS,WRITE TO US

Just tell us your requirements, we can do more than you can imagine.

whatsapp email
×