TS8216 Benchtop Spectrophotometer

TS8216 benchtop spectrophotometer uses a dual-array CMOS image sensor with higher sensitivity and a wider spectral response range, and the test is more accurate. The repeatability ΔE*ab of the TS8216 benchtop spectrophotometer is easily controlled within 0.01, and the inter-instrument errorΔE*ab is controlled within 0.12. The data is stable and reliable, and can be used for accurate color analysis and
transmission in the laboratory.

Inquiry
(+86)010-5653 8958
  • Product description
  • Product parameter
  • Product video

TS8216 Benchtop Spectrophotometer


TS8296:8216-内容.jpg

Features:

1. Micropore aperture

TS8216 benchtop spectrophotometer provides reflection: Φ0.3mm/Φ0.5mm/Φ1mm (only choose one aperture) Transmission: Φ8mm/Φ4mm (only choose one aperture), used for small area reflection samples and small volume transmission samples chromaticity control.

TS8216-特点1.jpg

2. It adopts the internationally-used D/8 structure, compatible with SCI/SCE measurement, and supports SCI+SCE rapid measurement at the same time

The TS8216 benchtop spectrophotometer adopts the internationally applicable D/8 illumination observation conditions, SCI/SCE (including specular reflection/not including specular reflection) synthesis technology, and supports SCI+SCE simultaneous rapid measurement.


TS8216-特点2.jpg

3. Dual array CMOS image sensor

With high sensitivity and wide spectral response range, it ensures the measurement speed, accuracy, stability and consistency of the instrument.

TS8216-特点3.jpg

4. Multiple color measurement spaces, multiple observation light sources

TS8216 benchtop spectrophotometer provides CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 color space, as well as D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 multiple observation light sources, which can meet the special measurement requirements under different measurement conditions.

TS8216-特点4.jpg

5. Adopt a combined full-spectrum LED light source and UV light source

The full-band balanced LED light source ensures sufficient spectral distribution in the visible light range, avoids the lack of spectrum of white light LEDs in specific wavelength bands, and ensures the measurement speed of the instrument and the accuracy of the measurement results. Professional UV light sources ensure UV testing more reliable.

TS8216-特点5.jpg

 6. Metrological verification report

Each TS8296 benchtop spectrophotometer has been verified and tested, and the instrument is verified according to the measurement standards of the authoritative verification department at the factory, and the measurement data is traced to the National Institute of Metrology to ensure the authority of the instrument test data.

7. Industrial-grade high-definition touch screen, easy-to-use user interface

Using a 7-inch industrial-grade high-definition touch screen, the control is smooth, and the easy-to-use user interface makes the operation comfortable, convenient and easier to use.

TS8216-特点7.jpg

8. Color management software

The SQCX quality management software matched with the TS8296 benchtop spectrophotometer is suitable for quality monitoring and color data management in various industries. Data the user's color management, compare color differences, generate test reports, provide a variety of color space measurement data, and customize customer color management.

TS8216-特点8.jpg


Application:

The TS8216 benchtop spectrophotometer is equipped with four measuring apertures of 25.4mm, 15mm, 8mm, and 4mm, which is suitable for more samples to be tested and meets the requirements of reflective samples and transparent samples in plastic electronics, paint and ink, textile and garment printing and dyeing, printing and other industries; it can be used for fluorescent sample measurement.

Model
TS8216
Optical Geometry
Reflect: di:8°, de:8°((diffuse illumination, 8°direction reception) ;

SCI (specular component included)/SCE (specular component excluded) ;Include UV/exclud UV

Transmittance: di:0°, de:0° (diffuse illumination: 0°direction reception) ;

SCI (specular component included)/SCE (specular component excluded) ; Include UV/exclud UV

Haze(ASTM D1003),

Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7
Application
It is used for the color control of small-area reflective samples and small-volume transmission samples.
Integrating Sphere Size
Φ154mm
Light Source
360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nm cut-off light source
Spectrophotometric Mode
Concave Grating
Sensor
256 Image Element Double Array CMOS Image Sensor
Wavelength Range
360-780nm
Wavelength Interval
10nm
Semiband Width
5nm
Measured Reflectance Range
0-200%
Measuring Aperture
Reflective : Φ0.3mm/Φ0.5mm/Φ1mm (only choose one aperture)

Transmissive : Φ8mm/Φ4mm (only choose one aperture)
Specular Component
Reflectance: SCI/SCE, Transmittance: SCI/SCE
Color Space
CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
Other Colorimetric Index
WI (ASTM E313, CIE/ISO, AATCC, Hunter),

YI (ASTM D1925, ASTM 313),

Metamerism index Mt,

Staining Fastness, Color Fastness, Color Strength, Opacity,

APHA/Hazen/Pt-Co (Platinum Cobalt Index), Gardner Index

8° gloss, 555 color classification, haze (ASTM D1003), Saybolt (Sybert index), ASTM D1500 color scale, Chinese Pharmacopoeia color
scale
Observer Angle
2°/10°
Illuminant
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30
Displayed Data
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring Time
About 2.4s (Measure SCI & SCE about 5s)
Repeatability
Spectral reflectance: Φ1mm/SCI, Standard deviation within 0.08%

Chromaticity value:Φ1mm/SCI, Standard deviation within ΔE*ab 0.15 (After the instrument is warmed up and calibrated, measure the
average value of the whiteboard 30 times at an interval of 5s)

Spectral transmittance: Φ8mm/SCI, Standard deviation within 0.1%

Chromaticity value:Φ8mm/SCI, Standard deviation within ΔE*ab 0.18(After the instrument is warmed up and calibrated, measure the
average value of the whiteboard 30 times at an interval of 5s)
Inter-instrument Error
Φ1mm/SCI, Within ΔE*ab 0.25(Measured average value of 12 tiles of BCRA series Ⅱ)
Dimension
L*W*H=370x300x200mm
Weight
Approx. 9.6kg
Power
AC 24V, 3A Power adapter power supply
Illuminant Life Span
5 years, more than 3 million times measurements
Display
7-inch TFT color LCD, Capacitive Touch Screen
Data Port
USB, Bluetooth®5.0, print serial port