The YSI ProDSS (digital sampling system) is a portable water quality multiparameter instrument for the measurement of several critical parameters - dissolved oxygen (optical), total algae, turbidity, pH, ORP, conductivity, specific conductance, salinity, TDS, resistivity, TSS, ammonium, ammonia, chloride, nitrate, depth (optional), temperature and GPS coordinates.
YSI-ProDSS
Multiparameter Digital Water Quality Meter
The YSI ProDSS (digital sampling system) handheld multiparameter meter provides extreme flexibility with two main cable options. Choose between the fully loaded 4-port cable assembly outfitted with any four DSS sensors (with depth or no depth) or the ODO/CT probe and cable - where you get accurate DO measurements every time with an optical dissolved oxygen sensor with an inline conductivity sensor, allowing for real-time salinity compensation.
Features:
* Designed for use in applications such as surface water, groundwater, coastal/estuarine, aquaculture, and wastewater, the rugged and reliable ProDSS allows for the measurement of water quality parameters with digital sensors. The ProDSS water quality meter uses smart sensor technology that allows sensors to be automatically recognized by the handheld while retaining calibration data.
* An easy-to-read backlit color display, large memory capacity, simple calibration procedures, rechargeable battery and powerful data management program (KorDSS) all help to make your sampling experience more convenient.
* The optional GPS and depth along with a wide range of cables and sensors (sold separately) allows for complete customization of the ProDSS. Military spec connectors, IP-67 waterproof rating, rubber over-molded case and 1-meter drop tests ensures durability to provide years of sampling even in the harshest field conditions.
Benchtop | Yes, optical BOD probe for the lab is available |
Buffer Recognition | Yes, auto-buffer recognition for USA (4.00, 7.00, 10.00) and NIST (4.01, 6.86, 9.18) buffer sets. Calibration values are automatically compensated for temperature for both buffer sets. |
Certifications | FCC, WEEE, UN Part III Section 38.3 test methods for lithium-ion batteries (class 9), RoHS, Assembled in USA, IP-67, 1-meter drop test, CE |
Connectivity / Communications | Built-in micro USB On-The-Go port for PC connection, recharging/powering the ProDSS and connecting directly to a USB stick |
Connector | MS (military spec) waterproof with quarter-turn bayonet lock (unsurpassed in regards to durability) |
Data Management | KorDSS desktop PC software (included), >100,000 data sets |
Desktop Software Compatible | KorDSS desktop PC software (included) |
Digital / Digital Sensors | Yes |
Flow Cell | Yes, flow cell is available |
GLP Compliance | detailed GLP information is stored and is available to view, download or print, Yes |
GPS | coordinates are stored with measurement data and site lists, Optional internal GPS |
Graphic Display | Color, LCD graphic display, backlit keypad |
Languages | Italian, German, Norwegian, English, French, Portuguese, Japanese, Chinese (Simplified & Traditional), Spanish |
Logging Capabilities | Single point or Continuous, Yes |
Measurement Method / Channels | Digital |
Memory | >100,000 data sets, 400 GLP files |
Multiparameter | Yes |
Operating Temperature | 0 to 50C (32 to 122F) |
Parameters Measured | Dissolved Oxygen (%), Dissolved Oxygen (mg/L), Temperature, Turbidity, Conductivity, Specific Conductance, Resistivity, Salinity, Water Density, pH, ORP, Ammonium, Nitrate, Chloride, Total Dissolved Solids (TDS), Total Suspended Solids (TSS), Depth, Barometer |
Power | Rechargeable lithium-ion battery pack providing ~48 hours of battery life (instrument only with backlight off) |
Sampling | Yes |
Security / Password Protection / UserID | Yes |
Size | Instrument: 8.3 cm width x 21.6 cm length x 5.6 cm depth (3.27 in x 8.5 in x 2.21 in) |
Bulkhead with sensors, without depth (no guard): 33.3 cm (13.11 in) length - the length with the ISE sensors is 34.04 cm (13.4 in) | |
Bulkhead with sensors, with depth (no guard): 35.84 cm (14.11 in) length - the length with the ISE sensors is 36.58 cm (14.4 in) | |
Bulkhead with guard, without depth: 42.82 cm (16.86 in) length and 4.75 cm (1.87 in) outer diameter | |
Bulkhead with guard, with depth: 45.36 cm (17.86 in) length and 4.75 cm (1.87 in) outer diameter | |
Smart Sensors / Ports | 4 universal sensor ports on each cable, can accept any ProDSS sensor, Yes |
Storage Temperature | 0 to 45C (32 to 113F) with battery installed0 to 60C (32 to 140F) without battery installed |
User Calibratable | Yes |
User Replaceable | Yes |
Warranty | 3-year instrument; 2-year bulkhead, cable assembly, and sensors; 1-year pH and pH/ORP sensor modules, ODO (opticalDO) sensor caps, and Li-Ion battery pack; 6-months ammonium, nitrate, and chloride sensor modules |
Waterproof | floats, IP-67 (even with the battery cover off) |
ProDSS System Specifications (Instrument, Cables & Sensors):
Parameter(units) | Sensor Type | Range | Accuracy | Resolution | Calibration | MaximumDepth |
Dissolved Oxygen (% saturation) | Optical Luminescence - Lifetime Method | 0 to 500% | 0 to 200% (±1% of reading or 1% air saturation, whichever is greater) 200% to 500% (±8% of reading) | 0.1% or 1% air saturation (user selectable) | 1 or 2 points | 100 m |
Dissolved Oxygen (mg/L, ppm) temp comp range -5 to 50°C | Optical Luminescence - Lifetime Method | 0 to 50 mg/L | 0 to 20 mg/L (±0.1 mg/L or 1% of reading, whichever is greater) 20 – 50 mg/L (±8% of reading) | 0.1 or 0.01 mg/L (user selectable) | 1 or 2 points (user selectable) | 100 m |
Temperature (°C, °F, K) | Thermistor; Combination Sensor with Conductivity | -5 to 70°C (23 to 158°F) | ±0.2°C | 0.1°C or 0.1°F (user selectable) | None | 100 m |
Turbidity (FNU, NTU) | Nephelometric - Optical, 90° Scatter | 0 to 4000 FNU | 0 to 999 (0.3 or ±2% of reading, whichever is greater) 1000 to 4000 (±5% of reading) | 0.1 FNU | 1, 2, or 3 points (user selectable) | - |
Conductivity* (µS, mS) | Four Nickel Electrode Cell | 0 to 200 mS/cm | 0 to 100 mS/cm (±0.5% of reading or 0.001 mS/cm, whichever is greater) 100 to 200 mS/cm (±1% of reading) | 0.001, 0.01 or 0.1 mS/cm (range dependent) | 1 point | 100 m |
Specific Conductance (µS, mS) | Calculated from Conductivity and Temperature | 0 to 200 mS/cm | ±0.5% of reading or 0.001 mS/cm, whichever is greater | 0.001, 0.01, 0.1 mS/cm | 1 point | - |
Resistivity (ohm-cm, kohm-cm, Mohm-cm) | Calculated from Conductivity and Temperature | 0 to 2 Mohms | ±0.1% Full Scale | 0.001, 0.01, 0.1 ohms | - | - |
Salinity (ppt, PSU) | Calculated from Conductivity and Temperature | 0 to 70 ppt | ±1.0% of reading or ±0.1 ppt, whichever is greater | 0.01 ppt | 1 point | - |
Water Density (Sigma, Sigma T) | Sigma is Calculated from Salinity, Temperature, and Pressure Sigma T is Calculated from Salinity and Temperature | 0.0 to 50.0 sigma, sigma T | - | 0.1 sigma or sigma T | - | - |
pH (mV, pH units) | Glass Bulb Combination Electrode; Ag/AgCl Reference Gel | 0 to 14 units | ±0.2 units | 0.01 units | 1, 2, or 3 points (user selectable) | 100 m |
ORP (mV) | Platinum Button; Ag/AgCl Reference | --1999 to +1999 mV | ±20 mV | 0.1 mV | 1 point | 100 m |
Ammonium** (NH4-N mg/L, NH4-N mV) ammonia with pH sensor | Ion Selective Electrode | 0 to 200 mg/L NH4-N | ±10% of reading or 2 mg/L, whichever is greater | 0.01 mg/L | 1, 2, or 3 point (user selectable) | 20 m |
Ammonia*** (NH3-N mg/L) | Calculated from Ammonium, Temperature, Salinity and pH | 0 to 200 mg/L NH4-N | - | 0.01 mg/L | - | - |
Nitrate** (NO3-N mg/L, NO3-N mV) | Ion Selective Electrode | 0 to 200 mg/L NO3-N | ±10% of reading or 2 mg/L, whichever is greater | 0.01 mg/L | 1, 2, or 3 point (user selectable) | 20 m |
Chloride** | Ion Selective Electrode | 0 to 18000 mg/L Cl | ±15% of reading or 5 mg/L, whichever is greater | 0.01 mg/L | 1, 2, or 3 point (user selectable) | 20 m |
Total Dissolved Solids (TDS) (mg/L, kg/L, g/L) | Calculated from Conductivity and Temperature | 0 to 100 g/L | User-Selectable TDS Multiplier (0.30 to 1.00; 0.65 default) | 0.001, 0.01, 0.1g/L | - | - |
Total Suspended Solids (TSS) (mg/L) | Correlated from Turbidity Field Measurements and Lab TSS Measurements from Grab Samples | 0 to 30000 mg/L | Calculated from Turbidity and User-Entered Correlation Points | 0.01, 0.1 mg/L | - | - |
Chlorophyll (RFU or µg/L chl) | Optical Luminescence | 0 to 100 RFU or 0 to 400 µg/L chl | Linearity: r2 ≥ 0.999 for Rhodamine WT across full range | 0.01 RFU or 0.01 µg/L chl | 2 point | - |
Phycocyanin (RFU or µg/L PC) | Optical Luminescence | 0 to 100 RFU or 0 to 100 µg/L PC | Linearity: r2 ≥ 0.999 for Rhodamine WT across full range | 0.01 RFU or 0.01 µg/L PC | 2 point | - |
Phycoerythrin (RFU or µg/L PE) | Optical Luminescence | 0 to 100 RFU or 0 to 280 µg/L PE | Linearity: r2 ≥ 0.999 for Rhodamine WT across full range | 0.01 RFU or 0.01 µg/L PE | 2 point | - |
Depth (m, ft) | Pressure Transducer | 0 to 100 m (0 to 328 ft) | ±0.004 m (±0.013 ft) for 1, 4 and 10-m cables ±0.04 m (±0.13 ft) for cables 20-m and longer | 0.001 m or 0.01 ft | 1 point | - |
Barometer (mmHg, inHg, mbar, psi, kPa, ATM) | Piezoresistive | 375 to 825 mmHg | ±1.5 mmHg from 0 to 50°C | 0.1 mmHg | 1 point | - |