Laboratory General Purpose Refillable ORP/RedOx Electrode

IntelliCAL MTC30101 


MTC30101-内容1.jpg

IntelliCALⓇ MTC301 is a digital combination oxidation reduction potential (ORP/RedOx) electrode with built-in temperature sensor. The MTC301 has a refillable with a ceramic pin reference junction. The laboratory version of this metallic electrode is shockproof with its epoxy plastic body protecting down to the platinum sensing element. The Electrode is available with a 3 or 1 m cable. The MTC301 electrode is ideal for measuring ORP/RedOx absolute mV values in wastewater, drinking water and aqueous media applications. The MTC101 is not suitable for use with organic solvents. A 59 mL bottle of reference electrolyte filling solution (3M KCl solution saturated with AgCl) is included with the probe.


PHC20101-内容2.jpg


* Provides fast, stable response in a variety of applications

*  Ultimate traceability in measurement history
* User alerted when re-calibration is needed
*  Can be moved between meters without the need to re-calibrate or re-enter measurement settings



Accuracy
±0.02 mV or 0.05%, whichever is greater
Cable Length
1 m (3.28 ft)
Electrode Type
Refillable Reference Element
Filling Solution
3 M KCl solution saturated with AgCl (#2841700)
Junction
Porous Pin Junction
Kit?
No
Length
175 mm (6.89 in.)
Method Type
Laboratory: Refillable Reference Element
Parameter
ORP
Probe Type
Standard
Product Kit
Model: MTC301
Accessories Included: None
Range
±1200 mV
Reference Type
Ag/AgCl
Resolution
±0.1 mV
Sample depth
20 mm (0.79 in.)
Sensor material
Epoxy
Sensor Type
Platinum disc
Special Features
Flat disc sensor for easy cleaning.
Temperature Accuracy
±0.3 °C (±0.54 °F)
Temperature Range
0 - 80 °C (32 - 176 °F)
Temperature Resolution
0.1 °C (0.18 °F)
Test requirements
Parameter Needed: ORP
Minimum Sample Depth (mm): 20
Thermistor
ATC
Weight
0.1 kg
What's included?
IntelliCAL MTC301 Laboratory ORP/RedOx electrode with storage soaker bottle, 1 m cable, 59-mL bottle reference electrolyte filling
solution 3M KCl with saturated AgCl solution), Test certificate, and Basic User Manual.