Wavelength range:360-780nm
Repeatability Accuracy dE*ab≤0.01
Inter-Instrument Agreement dE*ab≤0.12
DS-26D Portable spectrophotometer
DS-26D Portable spectrophotometer with wide wave length 360-780nm and high repeatability dE*ab≤0.01. Except black and white calibration , add BCRA green plate calibration to ensure the consistency of instrument. To cope with different usage scenarios,it comes with 6 measuring apertures : 11mm, 10mm, 6mm, 5mm, 3mm, and 1*3mm diameter.
Features
Industry-leading wavelength range:360-780nm
The wavelength range of conventional colorimeter is 400-700nm. In order to achieve moreAdd precise color measurement and extend the wavelength to 360-780nm.
Outstanding stage-to-stage variation and repeatability
The inter-stage difference is 0.12, which helps improve the color quality between manufacturers and suppliers.
The repeatability is 50% higher than the previous generation, reaching 0.01.
Dual light source system provides longer service life than expected
Use xenon lamp and LED to provide sufficient ultraviolet and visible light at the same time energy and ensure a measurement life of tens of millions of times.
Provides 6 measuring apertures to easily measure samples of different shapes
Six hole specifications: 11mm, 10mm, 6mm, 5mm, 3mm, 1*3mm diameter, very small objects or curved surface samples can also be easily measured.
BCRA green plate wavelength calibration
Automatic wavelength accuracy calibration using reference grade BCRA green plate correct to ensure that the instrument is consistent.
Indication accuracy increased by 60%
Using a new generation of array silicon light sensor, the amount of light input is increased 65%, spectral resolution increased by 39%, compared with the previous generation The indication accuracy is increased by 60%.
Built-in high-definition camera to clearly observe the measured area
During measurement, the DS-26D spectrophotometer can obtain an image of the measured area by opening the camera, clearly positioning the measured area of the sample, and avoiding inaccurate
measurements caused by regional errors.
Intelligent automatic calibration
Frequent manual calibration is not required during use, as long as the calibration On the accurate base, the instrument will automatically adjust according to its own status and environmental factors.Calibrate the overall instrument function and accuracy to ensure that the instrument The device is always in a stable state and ready for use at any.
Product model | DS-26D |
Measuring structure※
| D/8,SCI+SCE |
Light source life | 10 million times |
Wavelength range | 360-780nm |
SCI+SCE Measure simultaneously | support |
Calibration method | BCRA certified black and white board energy calibration, green board wavelength accuracy calibration |
Measurement repeatability※※ | dE*ab≤0.01 |
Inter-Instrument agreement※※※ | dE*ab≤0.12 |
Display accuracy | 0.01 |
Lighting source | Full-band balanced LED light source + xenon lamp |
UV light source | Yes |
Caliber | Φ11mm,Φ10mm,Φ6mm,5mm,Φ3mm,1mm*3mm |
Measurement standard | Spectral reflectance, CIE-Lab, CIE-LCh, HunterLab, CIE-Luv, XYZ, Yxy, RGB color difference (ΔE*ab, ΔE*cmc, ΔE*94, ΔE*00), munsell, hiding power, whiteness (ASTM E313-00, ASTM E313-73, CIE, ISO2470/R457, AATCC, Hunter, Taube Berger Stensby), yellowness (ASTM D1925, ASTM E313-00, ASTM E313-73) blackness (My, dM), stain fastness, discoloration fastness, Tint (ASTM E313-00) color density CMYK (A, T, E, M), metamerism index milm, strength (dye strength, tinting strength) |
Light source conditions | A,B,C,D50,D55,D65,D75F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12CWF,U30,U35,DLF,NBF,TL83,TL84,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2 |
Observation method | Camera |
Calibration | Intelligent automatic calibration |
Software support | Android, iOS, Windows, WeChat applet |
Accuracy guaranteed | Guarantee first-level measurement qualification |
Standard observer | 2°,10° |
Integrating sphere diameter | 40mm |
Standards | CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
Spectral method | grating |
Sensor | Dual column high-precision CMOS array sensor |
Wavelength interval | 10nm |
Reflectivity measurement range | 0-200% |
Reflectance resolution | 0.01% |
Measuring time | about 1 second |
Interface | USB, Bluetooth |
Screen | Full color screen, 3.5 inches |
Battery capacity | Can continuously measure 8000 times on a single charge, 7.2V/3000mAh |
Language | Simplified Chinese, English |
Storage | Instrument: 10,000 items; APP: Mass storage |
Size | 233mm*77mm*93mm |
Weight | About 600g |